Fault Diagnosis and Maintenance Skills of Water Ring Vacuum Pump

News


During the inspection, the fault diagnosis of the water ring vacuum pump is the key link. The following are some common faults and solutions proposed by our factory Hu Gong. The following will share with you the fault diagnosis and maintenance skills of the water ring vacuum pump and wish you an early solution to the thorny problems.

During the inspection, the fault diagnosis of the water ring vacuum pump is the key link. The following are some common faults and solutions proposed by our factory Hu Gong. The following will share with you the fault diagnosis and maintenance skills of the water ring vacuum pump and wish you an early solution to the thorny problems.

16148457082874.jpg

1. If there is no supply of liquid, or the supply of liquid and pressure is insufficient.

If the vacuum pump is not filled with water or exhausted.

Solution: Need to check the housing and inlet pipeline of the vacuum pump

The speed is too low

Solution: Need to check the wiring out of the motor, the voltage and the steam pressure of the turbine.

System head too high

Solution: Check the head of the friction loss.

The adsorption capacity is too high.

Solution: Check the existing pure pressure head (if the inlet pipe is too small or too long, it will produce greater friction loss)

Impeller and pipe blockage

Solution: Check whether there are any obstacles.

Wrong direction of rotation

Solution: Check the direction of rotation.

Check the inlet line for leaks.

Solution: Whether there is leakage in the inlet pipeline.

The sealing ring and seal in the sealing ring are worn, causing the vacuum pump housing to leak.

Solution: check the seal when necessary to replace, check whether the lubrication is normal.

Insufficient suction head when sucking starting liquid;

Solution: Need to increase the suction head.

Bottom valve too small

Solution: Install the bottom valve according to the correct size. Insufficient immersion depth of foot valve or inlet pipe

Solution: Use the correct immersion depth.

The clearance of the impeller is too large

Solution: Check the gap position

Damaged impeller

Solution: Check the impeller and replace it if necessary.

The diameter of the impeller is too small

Solution: Use the correct impeller diameter.

Incorrect position of pressure gauge.

Solution: Need to check the outlet nozzle or pipe.

2. The vacuum pump stops running for a while.

The adsorption capacity is too high

Solution: Check the existing pure pressure head (if the inlet pipe is too small or too long, it will produce greater friction loss)

Impeller and pipe blockage

Solution: Check for obstacles.

The above is the fault diagnosis and maintenance skills of the water ring vacuum pump. If the problem of the water ring pump still cannot be solved, please pay attention to our company. Develop the best solution for free